Underwater Lights
High voltage pool/spa lights require GFCI protection. To meet electrical code requirements,
the pool/spa light must be connected directly to the GFCI. Do not use a GFCI circuit breaker.
To wire high voltage pool/spa light
1. Install a GFCI receptacle next to the Sub-panel.
2. Connect neutral and hot wire from circuit breaker to the LINE SIDE of the GFCI
receptacle.
3. Connect white wire from the light to the LOAD SIDE of the GFCI receptacle.
4. Connect the other wire from the light to LOAD 1 of the relay terminal block.
5. Connect a wire from LINE 1 of the relay terminal block to the LOAD SIDE of the GFCI
receptacle.
Note
The example above assumes the pool or spa light is 500 watts or less. If the pool has two
500 watt lights, the second light needs to be wired to LOAD 2 of the relay terminal block. Install
a jumper wire between LINE 1 and LINE 2 of the relay terminal block.
LINE 1
LINE 2
LOAD 1
LOAD 2
R1
LINE 1
LINE 2
LOAD 1
LOAD 2
R2
LINE 1
LINE 2
LOAD 1
LOAD 2
R3
LINE 1
LINE 2
LOAD 1
LOAD 2
R4
LINE 1
LINE 2
LOAD 1
LOAD 2
R5
LINE 1
LINE 2
LOAD 1
LOAD 2
R6
LINE 1
LINE 2
LOAD 1
LOAD 2
R7
HIGH VOLTAGE RELAYS
FULL LOAD: 20AMP
LOCKED ROTOR: 60AMP
Lx3810
SUB-PANEL
GFCI
TO LIGHT
Filter
Pump
Heater
6
5
4
3
2
1
P
Solar
Auto
Service
IMPORTANT: Switch back to
Auto after servicing equipment.
Water Sensor
Solar Sensor
Sensor
Status
Auto
Auto
Service
Press Filter key 2 times quickly.
Filter Pump On:
Press Filter key 3 times quickly.
Filter Pump Off:
To cancel:
The 3-hour override can be
cancelled by switching to
Service, and then back to Auto.
Make sure the Auto/Service
key is in the Auto position.
Override Verification:
The Auto lamp will blink
during the 3-Hour Override.
Instructions:
When adding chemicals, the filter
pump can be set to stay on for three
hours -or- stay off for three hours.
This overrides the programming of
the Cp3810 indoor controller on a
one-time basis. The same procedure
can be used on the other equipment
keys 1-6.
3 Hour Filter Override
P
P
B
Freeze Sensor
Lamp ON indicates problem with the
sensor or wires leading to sensor.
Check connections and replace sensor
if necessary.
B.wash